Let an external system trigger your compatible HiSpec alarm installation. The HSSA/INPUTMODULE accepts a normally open, volt-free contact input: when the external contact closes, it triggers the connected fire/CO alarm system through the wired interconnect.
This can provide an interface from an appropriately designed sprinkler system or EN54 fire panel with a suitable dry-contact output. The module fits a compatible HiSpec Fast Fix base and is supplied with a cover. A qualified installer must confirm the signal, wiring and system operation.
Choose this module when a signal needs to enter the HiSpec system. To make a HiSpec alarm operate an external sounder or beacon, use a mains relay base or an RF10-PRO relay base instead. The input module has no built-in wireless pairing or detector.
Key Specifications
| Product Code | HSSA/INPUTMODULE |
|---|---|
| Supply | 230V AC, 50/60Hz, 50mA |
| Backup | 3V sealed rechargeable lithium battery |
| Product Life | 10 years |
| Input | Normally open volt-free contact (IN–SW) |
| Material | ABS |
| Operating Temperature | −10°C to +40°C |
| System Planning | Up to 20 compatible HiSpec fire devices; observe the lowest device and wiring limit in the system |
Compatible Wired Alarm Options
- HSSA/PE/FF — Interconnectable Fast Fix Mains Smoke Alarm With 9V Battery Backup
- HSSA/HE/FF — Interconnectable Fast Fix Mains Heat Alarm With 9V Battery Backup
- HSSA/CO/FF — Fast Fix Mains Carbon Monoxide Alarm With 9V Battery Backup
- HSSA/PE/FF10 — Fast Fix Mains Smoke Alarm With 10 Year Lithium Backup
- HSSA/HE/FF10 — Fast Fix Mains Heat Alarm With 10 Year Lithium Backup
- HSSA/CO/FF10 — Fast Fix Mains Carbon Monoxide Alarm With 10 Year Lithium Backup
- HSSA/PH/FF10 — Fast Fix Mains Smoke & Heat Alarm With 10 Year Lithium Backup
- HSSA/HCO/FF10 — Fast Fix Mains Heat & Carbon Monoxide Alarm With 10 Year Lithium Backup






Recensioner